Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
J Craniofac Surg ; 30(7): 2076-2081, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31490436

RESUMO

This study aims to assess the morphological appearance, incidence of bridging, linear dimensions of sella turcica and establish cephalometric standards in Bosnian, Chinese and Nepalese subjects. This retrospective study examined digital standardized lateral cephalograms of 540 subjects, which consisted of 116 females and 64 males with an age range of 8 to 28 years. The sella morphology, bridging, and size were analyzed on the lateral cephalograms. Steiner's and Rickett's analyses were performed on 270 subjects. Sella turcica presented a normal morphology in most Bosnian (86.7%), and Nepalese (90%) subjects whereas flat-shaped morphology was highly prevalent among Chinese subjects (36.7%). The frequency of full bridging was 7.2%, 2.8%, and 11.7% for Bosnian, Chinese, and Nepalese subjects, respectively. A significant correlation was detected between the length of sella turcica and gender of Bosnian subjects, whereas the size of sella turcica and gender of Chinese and Nepalese subjects were not affected. A direct correlation existed between age and size of sella turcica of Bosnian subjects. A significant correlation was detected between length and diameter of sella turcica and age in Chinese and Nepalese subjects. A statistically significant difference was found in length (P < 0.001), depth (P < 0.01) and diameter (P < 0.001) of sella turcica with race. The diameter of sella turcica was the only parameter significantly associated with race, gender and age. Significant differences were found between cephalometric norms in different racial groups. These findings assist orthodontists, neurosurgeons, and forensic medical investigatiors during orthodontic treatment planning, diagnosis of pathology of the pituitary gland, and age determination.


Assuntos
Cefalometria , Sela Túrcica/anatomia & histologia , Adolescente , Adulto , Criança , Feminino , Humanos , Incidência , Masculino , Radiografia , Estudos Retrospectivos , Adulto Jovem
2.
J Adv Prosthodont ; 11(1): 65-74, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30847051

RESUMO

PURPOSE: To evaluate and compare the effect of different materials and techniques on the shear bond strength of veneering ceramic materials to zirconia. MATERIALS AND METHODS: 136 sintered zirconia cubes were prepared and randomly divided into four study groups according to corresponding methods of surface treatment and materials: GLN (grinding followed by laser scanning using Noritake Cerabien ZR), SLN (sandblasting followed by laser scanning using Noritake Cerabien ZR), GLV (grinding followed by laser scanning using VITA VM 9), and SLV (sandblasting followed by laser scanning using VITA VM 9). Spraying technique was performed to coat the core. Profilometer, SEM, XRD, EDS, universal testing machine, and stereomicroscope were used to record surface roughness Ra, surface morphology, phase transformation, elemental compositions, shear bond strength SBS values, and failure types, respectively. Specimens were investigated in unaged (not immersed in artificial saliva) and aged (stored in artificial saliva for a month) conditions to evaluate SBS values. RESULTS: Grinding and GLN as first and second surface treatments provided satisfactory Ra values in both conditions (1.05 ± 0.24 µm, 1.30 ± 0.21 µm) compared to sandblasting and other groups (P<.05). The group GLN showed the highest SBS values in both conditions (30.97 ± 3.12 MPa, 29.09 ± 4.17 MPa), while group SLV recorded the lowest (23.96 ± 3.60 MPa, 22.95 ± 3.68 Mpa) (P<.05). Sandblasting showed phase transformation from t-m. Mixed failure type was the commonest among all groups. CONCLUSION: GLN showed to be a reliable method which provided satisfactory bond strength between the veneer ceramic and zirconia. This method might preserve the integrity of fixed dental crowns.

3.
J Appl Oral Sci ; 24(3): 258-63, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27383707

RESUMO

OBJECTIVE: This study compared the marginal gap, internal fit, fracture strength, and mode of fracture of CAD/CAM provisional crowns with that of direct provisional crowns. MATERIAL AND METHODS: An upper right first premolar phantom tooth was prepared for full ceramic crown following tooth preparation guidelines. The materials tested were: VITA CAD-Temp®, Polyetheretherketone "PEEK", Telio CAD-Temp, and Protemp™4 (control group). The crowns were divided into four groups (n=10), Group1: VITA CAD-Temp®, Group 2: PEEK, Group 3: Telio CAD-Temp, and Group 4: Protemp™4. Each crown was investigated for marginal and internal fit, fracture strength, and mode of fracture. Statistical analysis was performed using GraphPad Prism software version 6.0. RESULTS: The average marginal gap was: VITA CAD-Temp® 60.61 (±9.99) µm, PEEK 46.75 (±8.26) µm, Telio CAD-Temp 56.10 (±5.65) µm, and Protemp™4 193.07(±35.96) µm (P<0.001). The average internal fit was: VITA CAD-Temp® 124.94 (±22.96) µm, PEEK 113.14 (±23.55) µm, Telio CAD-Temp 110.95 (±11.64) µm, and Protemp™4 143.48(±26.74) µm. The average fracture strength was: VITA CAD-Temp® 361.01 (±21.61) N, PEEK 802.23 (±111.29) N, Telio CAD-Temp 719.24 (±95.17) N, and Protemp™4 416.40 (±69.14) N. One-way ANOVA test showed a statistically significant difference for marginal gap, internal gap, and fracture strength between all groups (p<0.001). However, the mode of fracture showed no differences between the groups (p>0.05). CONCLUSIONS: CAD/CAM fabricated provisional crowns demonstrated superior fit and better strength than direct provisional crowns.


Assuntos
Resinas Acrílicas , Resinas Compostas , Desenho Assistido por Computador , Coroas , Adaptação Marginal Dentária , Planejamento de Prótese Dentária/métodos , Cetonas , Polietilenoglicóis , Análise de Variância , Benzofenonas , Falha de Restauração Dentária , Teste de Materiais , Polímeros , Valores de Referência , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Fraturas dos Dentes
4.
J. appl. oral sci ; 24(3): 258-263, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-787543

RESUMO

ABSTRACT Objective This study compared the marginal gap, internal fit, fracture strength, and mode of fracture of CAD/CAM provisional crowns with that of direct provisional crowns. Material and Methods An upper right first premolar phantom tooth was prepared for full ceramic crown following tooth preparation guidelines. The materials tested were: VITA CAD-Temp®, Polyetheretherketone “PEEK”, Telio CAD-Temp, and Protemp™4 (control group). The crowns were divided into four groups (n=10), Group1: VITA CAD-Temp®, Group 2: PEEK, Group 3: Telio CAD-Temp, and Group 4: Protemp™4. Each crown was investigated for marginal and internal fit, fracture strength, and mode of fracture. Statistical analysis was performed using GraphPad Prism software version 6.0. Results The average marginal gap was: VITA CAD-Temp® 60.61 (±9.99) µm, PEEK 46.75 (±8.26) µm, Telio CAD-Temp 56.10 (±5.65) µm, and Protemp™4 193.07(±35.96) µm (P<0.001). The average internal fit was: VITA CAD-Temp® 124.94 (±22.96) µm, PEEK 113.14 (±23.55) µm, Telio CAD-Temp 110.95 (±11.64) µm, and Protemp™4 143.48(±26.74) µm. The average fracture strength was: VITA CAD-Temp® 361.01 (±21.61) N, PEEK 802.23 (±111.29) N, Telio CAD-Temp 719.24 (±95.17) N, and Protemp™4 416.40 (±69.14) N. One-way ANOVA test showed a statistically significant difference for marginal gap, internal gap, and fracture strength between all groups (p<0.001). However, the mode of fracture showed no differences between the groups (p>0.05). Conclusions CAD/CAM fabricated provisional crowns demonstrated superior fit and better strength than direct provisional crowns.


Assuntos
Polietilenoglicóis , Resinas Acrílicas , Planejamento de Prótese Dentária/métodos , Desenho Assistido por Computador , Adaptação Marginal Dentária , Resinas Compostas , Coroas , Cetonas , Valores de Referência , Fraturas dos Dentes , Teste de Materiais , Reprodutibilidade dos Testes , Análise de Variância , Estatísticas não Paramétricas , Falha de Restauração Dentária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...